HI93728 - fotometer Nitraten

Omschrijving


HI 93728

Nitrates are present in nature as a result of decomposition of organic microorganisms or due to their use as fertilizers. Nitrates reduce to nitrites, which in turn easily combine to form substances dangerous to man.

A maximum level of 45 mg/L is established as a worldwide guideline for nitrate concentration in water. In Europe, the maximum consented level of nitrates in potable water is 50.0 mg/L, while in the USA the EPA has established a guideline for the maximum level of nitrate nitrogen of 10 mg/L (NO-³-N), which corresponds to 45.0 mg/L of nitrates.

The HANNA® solutions are HI 93728 and HI 93828, hand held meters suited for field measurement. Reading procedures have been made as simple as possible to allow everyone to perform accurate nitrate measurements.

The kit provides you with all you need for field measurement: photometer, reagents and apparatus perfectly fitted in a rugged carrying case

• HI 93728 reads nitrogen nitrate from 0 to 30 mg/L (NO-³-N); multiply the readout by a factor of 4.43 and you can read up to 133 mg/L of nitrate (NO-³).
• HI 93828 reads nitrate directly in mg/L of NO-³, from 0 to 100 mg/L.

With a normal 9V battery you will be able to get more than 300 measurements. The auto shut-off feature (after 10 minutes of non-use) guarantees a long battery life.

Specificaties


De technische specificaties van dit product:

Accuracy ±0.5 mg/L ±10% of reading
Battery Type / Life 1 x 9V / approx. 40 hours of continuous use;
auto-off after 10 minutes of non use
Dimensions 180 x 83 x 46 mm (7.1 x 3.3 x 1.8")
Environment 0 to 50°C (32 to 122°F); RH max 95% non-condensing
Light Detection Silicon Photocell
Light Life Life of the instrument
Light Source LED 555 nm
Method Adaptation of cadmium reaction method. The reaction between
nitrate-nitrogen and the reagent causes an amber tint in the sample
Range 0.0 to 30.0 mg/L (NO-³-N)
Resolution 0.1 mg/L
Weight 290 g (10 oz.)

Accessoires


Accessoires bij dit product:

   Oplossingen
HI93703-50 Reinigingsvloeistof voor cuvetten
   Accessoires
HI710009 Blauwe schokbestendig rubberen hoes
HI710010 Oranje schokbestendig rubberen hoes
HI731318 Doekje om cuvetten te reinigen (4 *)
   Reagentia
HI93728-01 reagent: Nitraten/bereik: 0.0-30.0 mg/L-± 100 tst.
HI93728-03 reagent: Nitraten/bereik: 0.0-30.0 mg/L-± 300 tst.

Andere producten


Selectie van andere producten uit de categorie Ion Fotometers:

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Downloads


Downloads bij dit product:

PDF icon  Download gebruikershandleiding

PDF icon  Download MSDS (datasheet)

PDF icon  Download documentatie (Proces en in-line)

Om de eventuele gebruikershandleiding, leaflet(s) en/of MSDS datasheet(s) te kunnen bekijken is Adobe Reader benodigd.

U kunt Adobe Reader gratis downloaden.